Specifying Expressions for Adaptive Convergence

You can specify additional convergence criteria through the use of expressions and output variables. The Max Delta or the Max Percent Delta defined for expression convergence represents the difference in values of the expressions between consecutive adaptive passes. If the difference in the value of the expression between consecutive passes is less than the Max Delta or the Max Percent Delta value this part of the convergence criteria is satisfied.

• For driven solutions, if the Maximum Delta S, Maximum Delta E, or alternate matrix convergence criteria are achieved in addition to any specified expression convergence criteria, the adaptive analysis stops. Otherwise, the solution continues until the requested number of passes is completed.

• For eigenmode solutions, if the Maximum Delta Frequency Per Pass criteria is achieved in addition to any specified expression convergence criteria, the adaptive analysis stops. Otherwise, the solution continues until the requested number of passes is completed.

To set expressions as Convergence criteria:

1. Double-click on the setup icon in the Project tree to open the Solution Setup dialog.

2. Click the Expression Cache tab in the Solution Setup and click the Add... button to open the Add to Expression Cache dialog.

[spacer]

3. Specify the context for the expression you define. For Modal Solution Data, you do not need context other than the Solution. Other selections require more context:

• Emission Test also requires a digital signal.

• Far Field field also requires a geometry such as an infinite sphere.

• Fields or Near Fields also require a geometry such as a polyline.

4. Under the Trace tab, select from the Category, Quantity and Function lists to create expressions.

Selecting a listed category lists the Quantities and Functions available for each category. If you have defined one or more output variables, you can see them listed as Quantities by selecting the Output Variables Category. The Output Variables button opens a dialog that lets you define additional output variables.

When you have created an expression, it appears in the Expression field of the Trace tab. If desired, you can use the Range Function button to select range functions to apply to the expression.

Under the Calculation Range tab, you can view the values of available sweep variables. Clicking the ellipsis [...] button in the Edit column opens a list of values.

5. When you have created an expression that you want to add to the cache, click the Add Calculation button.

This adds the selected expression and the associated context to a table in the Expression Cache tab. You can select any additional expressions with contexts and add them in the same way.

6. When you have added the expressions you want, click Done to close the Add to Expression Cache dialog.

The Expression Cache tab of the Solution Setup lists the expressions you have added as a table.

[spacer]

• The Title field is editable, by default showing the name as built from the expression, but removing underscores.

• The Expression field shows the full expression. If necessary, you can resize the Solution Setup dialog. You can also resize each column in the table.

• The Context column shows None for Modal solutions, or the appropriate geometry for Fields calculations.

• The PP Variables column contains a checkbox that lets you designate post processing variables, such as for renormalization or deembedding. You can also use this feature to assign variables to non-model objects (for example, the properties of a solid, sheet or lines used for field calculations). You can also assign a PP Variable to a coordinate system (CS) that is not associated with model objects.

To excite particular sources for particular output variables, you can assign a post process variable to the magnitude of sources you might want to edit, and assign the expression value in the Expression Cache. With PP Variables, you can control convergence based on several combinations of active sources.

• The Intrinsics column shows a clickable button that opens an Edit Calculation Range dialog. If the column button shows None you cannot edit the value. If the button shows variables, click the ellipsis [...] in the Edit column to display a list of the variable values that you can select. Click OK to close the Edit Calculation Range dialog and apply your selections to the Expression Cache.

7. To designate one or more expressions for convergence, click the field for the Convergence column for each expression.

This opens an Adaptive Convergence dialog.

[spacer]

Check Use this expression for convergence to enable the radio buttons. You can then specify the Max Delta between passes or the Max Percent Delta criteria. The Max Delta solves a potential issue if your expression is essentially zero and the numeric noise from pass to pass causes the maximum percentage delta to remain high. In that case adaptive refinement continues until you get to the maximum number of passes.

8. Click OK to close the Solution Setup dialog.

Related Topics

Viewing Convergence Data

Viewing the Output Variable Convergence

Specifying Output Variables

主站蜘蛛池模板: 再深点灬舒服灬在快点视频| 国产精彩视频在线| 久久免费精品一区二区| 欧美性xxxx偷拍| 免费A级毛片无码无遮挡| 色135综合网| 国产情侣真实露脸在线| 永久看日本大片免费35分钟| 天天躁日日躁狠狠躁av中文| 中文字幕日韩人妻不卡一区| 日韩精品一区二区三区毛片| 亚洲性久久久影院| 澡人人澡人澡人人澡天天| 初尝人妻少妇中文字幕| 色噜噜狠狠狠综合曰曰曰| 国产在线视频区| 免费观看无遮挡www的视频| 国产精品美女久久久浪潮av| 99无码精品二区在线视频| 婷婷综合激情网| 中文字幕亚洲专区| 日本人69视频jzzij| 久久综合九色综合欧美狠狠| 欧美丰满大乳大屁股流白浆| 亚洲激情视频网站| 片成年免费观看网站黄| 免费萌白酱国产一区二区| 美女毛片一区二区三区四区| 国产亚洲美女精品久久久久| 99re热久久这里只有精品首页| 国产精品久久毛片| 337p日本欧洲亚洲大胆艺术| 国自产偷精品不卡在线| free性俄罗斯| 女的扒开尿口让男人桶| 一级毛片特级毛片黄毛片| 成年人影院在线观看| 久久久99精品免费观看| 日本高清乱理伦片| 久久精品国产亚洲AV无码麻豆| 极品丝袜系列列表|