 HFSS online help > Post Processing and Generating Reports >
   Viewing Solution Data       

Viewing Matrix Data

To view matrices computed for the S-parameters, impedances, and propagation constants during each adaptive, non-adaptive, or sweep solution:

1. In the project tree, right-click the solution setup of interest, and then click Matrix Data on the shortcut menu.

The Solution Data dialog box appears. The Matrix Data tab is selected.

2. In the Design Variation text box, specify the design with the matrices you want to view.

Optionally, choose a design variation solved during an Optimetrics analysis from the Set Design Variation dialog box. This lists all the solved variations in the design. This dialog box is accessible from the Solution Data window by clicking the ellipsis button on the right of the Design Variation field, and via the >HFSS or HFSS-IE>Results>Apply Solved Variation command.

3. In the Simulation pull-down list, click the solution setup and solved pass - adaptive, single frequency solution, or frequency sweep - for which you want to view matrices.

4. Select the type of matrix you want to view: S-matrix, Y-matrix, Z-matrix, Gamma, or Zo (characteristic impedance.) The available types depend on the solution type.

5. Select the display format Magnitude/ Phase (deg), Real/ Imaginary, dB/ Phase (deg), Magnitude, Phase (deg), Real, Imaginary, or dB — in which to display the matrix information.

6. Select the solved frequencies to display:

• To display the matrix entries for all solved frequencies, select Display All Freqs.

If Display All Freqs is enabled, the drop-down frequency select list is disabled.

• To show the matrix entries for a selected solved frequency, ensure that Display All Freqs unchecked and use the dropdown list to select the solved frequency for which you want to view matrix entries. You can use a scroll bar for selecting from long frequency lists.

For adaptive passes, only the solution frequency specified in the Solution Setup dialog box is available. For frequency sweeps, the entire frequency range is available.

• To insert or delete one or more displayed frequencies, click Edit Freqs.

Note: This command is only available if the sweep type is Fast or Interpolating.

Clicking Edit Freqs displays the Edit Sweep dialog. It contains Generate New Values fields for specifying the Start Value, the End Value, and the Number of Values. The current values are displayed in a table. When you specify a New value, click Update Values to refresh the table.

Note: Changes to the Start Value and End Value cannot be outside of the initial range. No message is issued: rather the range is implicitly restricted.

Use the Insert button to add a new frequency to the table above the currently selected value. If no value, or the start value is selected, the new frequency repeats the current Start value and increments the count in the Number of Values field. If you select any other value for the insertion point, Insert adds a new value halfway between the selected value and the previous value, and increments the Number of Values field.

Incrementing or deincrementing the Number of Values fields, and the clicking Update Values updates the table based in the current Start and End value fields (given the range restriction within the initial range).

The Delete button enabled only if a value is selected. Delete removes the selected value and decrements the Number of Values field.

Click OK to apply the changes to the Solutions dialog Matrix Data tab and close the Edit Sweep dialog, or Cancel to close the dialog without applying the changes.

If you choose to export the matrix data for the Fast or Interpolating sweep after modifying the frequencies in the Edit Sweep dialog box, only those frequencies displayed under the Matrix Data tab will be exported.

The data is displayed in the table. By default, Waveports are listed in alphabetical, then numerical order, just as they appear in the excitation tree. To change the port order, change setting for Default Matrix sort order in the HFSS or HFSS-IE General options. You may also want see how you can Reorder Matrix Data.

7. Optionally, Check Passivity.

This passivity check tests whether the S-parameter data from HFSS is passive or not. If the S-Matrix is not passive at one or more frequencies, this check displays a dialog that identifies the worst frequency violation and identifies the passivity in that case.

Related Topics

Selecting the Matrix Display Format

Viewing Solution Data for an Optimetrics Design Variation

Exporting Matrix Data

Renaming Matrix Data

Reordering Matrix Data

Exporting Equivalent Circuit Data

Technical Notes: Passivity

 



HFSS教程     

Ansys HFSS,Ansoft HFSS online help,Version 15.0.

HFSS視頻教程HFSS教程專欄射頻工程師培訓(xùn)培訓(xùn)課程 : Viewing Matrix Data'>HFSSComments

主站蜘蛛池模板: 西西人体欧美大胆在线| 久久久亚洲av波多野结衣| 福利视频欧美一区二区三区| 日韩欧美卡一卡二卡新区| 亚洲色图综合网| 狠狠色欧美亚洲综合色黑a| 天堂在线www资源在线下载| 久久aa毛片免费播放嗯啊| 最近中文字幕国语免费完整| 亚洲欧洲日产国码AV系列天堂| 韩国朋友夫妇:交换4| 国产精品亚洲片在线| 99热这里只有精品国产动漫| 成人亚洲成人影院| 久久亚洲色www成人欧美| 欧洲精品码一区二区三区| 亚洲熟妇中文字幕五十中出| 福利小视频在线观看| 四虎影视精品永久免费网站| 91国高清视频| 女人双腿搬开让男人桶| 中文在线观看永久免费| 日本大乳高潮视频在线观看| 亚洲AV无码乱码国产精品| 精品久久久久久国产| 国产一级毛片国语普通话对白| 99久久99热精品免费观看国产| 性欧美xxxx| 中文无遮挡h肉视频在线观看| 日韩午夜伦y4480私人影院| 亚洲一卡2卡4卡5卡6卡在线99| 欧美综合一区二区三区| 人人妻人人澡人人爽曰本 | 搡女人真爽免费视频大全软件| 亚洲精品无码你懂的| 粉嫩大学生无套内射无码卡视频| 品色堂永久免费| 色婷婷综合激情视频免费看| 国产午夜精品一区二区三区不卡 | 精品国产无限资源免费观看| 国产精品国产自线拍免费软件|